Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Arq. neuropsiquiatr ; 73(3): 260-280, 03/2015. tab
Article in English | LILACS | ID: lil-741193

ABSTRACT

The Consensus on restless legs syndrome is an effort of neurologists from several Brazilian states, which tirelessly reviewed the literature of recent years in search of evidence, both in regard to diagnosis and treatment, according to the Oxford Centre for Evidence-based Medicine.


O Consenso em síndrome das pernas inquietas contou com a participação de neurologistas de vários estados brasileiros, os quais incansavelmente revisaram a literatura dos últimos anos em busca de evidências, tanto no que se refere ao diagnóstico como ao tratamento, de acordo com a Classificação do Centro de Oxford para Medicina Baseada em Evidências.


Subject(s)
Adolescent , Adult , Aged , Female , Humans , Male , Middle Aged , Young Adult , Kidney Calculi/surgery , Nephrostomy, Percutaneous/methods , Feasibility Studies , India , Nephrostomy, Percutaneous/adverse effects , Retrospective Studies , Treatment Outcome
2.
Braz. J. Psychiatry (São Paulo, 1999, Impr.) ; 32(3): 294-305, Sept. 2010. ilus, tab
Article in English | LILACS | ID: lil-560778

ABSTRACT

Este artigo relata as conclusões da reunião de consenso com médicos especialistas sobre diagnóstico de narcolepsia baseada na revisão dos artigos sobre narcolepsia listados no Medline entre 1980 e 2010. A narcolepsia é uma doença crônica de início entre a primeira e segunda décadas de vida do indivíduo. Os sintomas essenciais são cataplexia e sonolência excessiva. A cataplexia é definida como episódios súbitos, recorrentes e reversíveis de fraqueza da musculatura esquelética desencadeados por situações de conteúdo emocional. Os sintomas acessórios são alucinações hipnagógicas, paralisia do sono e sono fragmentado. Critérios de diagnóstico clínico de acordo com a Classificação Internacional dos Transtornos do Sono são de sonolência excessiva e cataplexia. Recomenda-se a realização de polissonografia seguida do teste de latência múltipla do sono em um laboratório de sono para confirmação e diagnóstico de comorbidades. Quando não houver cataplexia, deve haver duas ou mais sonecas com sono REM no teste de latência múltipla do sono. Tipagem HLA-DQB1*0602 positiva com níveis de hipocretina-1 abaixo de 110pg/mL devem estar presentes para o diagnóstico de narcolepsia sem cataplexia e sem sonecas com sono REM.


This manuscript contains the conclusion of the consensus meeting on the diagnosis of narcolepsy based on the review of Medline publications between 1980-2010. Narcolepsy is a chronic disorder with age at onset between the first and second decade of life. Essential narcolepsy symptoms are cataplexy and excessive sleepiness. Cataplexy is defined as sudden, recurrent and reversible attacks of muscle weakness triggered by emotions. Accessory narcolepsy symptoms are hypnagogic hallucinations, sleep paralysis and nocturnal fragmented sleep. The clinical diagnosis according to the International Classification of Sleep Disorders is the presence of excessive sleepiness and cataplexy. A full in-lab polysomnography followed by a multiple sleep latency test is recommended for the confirmation of the diagnosis and co-morbidities. The presence of two sleep-onset REM period naps in the multiple sleep latency test is diagnostic for cataplexy-free narcolepsy. A positive HLA-DQB1*0602 with lower than 110pg/mL level of hypocretin-1 in the cerebrospinal fluid is required for the final diagnosis of cataplexy- and sleep-onset REM period -free narcolepsy.


Subject(s)
Humans , Narcolepsy/diagnosis , Brazil , Diagnosis, Differential , Narcolepsy/etiology , Narcolepsy/genetics
3.
Arq. neuropsiquiatr ; 64(3a): 578-581, set. 2006. ilus, graf, tab
Article in English, Portuguese | LILACS | ID: lil-435589

ABSTRACT

The classification of short duration events in the EEG during sleep, as the A stage of the cyclic alternating pattern (CAP) is a tedious and error prone task. The number of events under normal conditions is large (several hundreds), and it is necessary to mark the limits of the events with precision, otherwise the time sensitive classification of the CAP phases (A and B) and specially the scoring of different types of A phases will be compromised. The objective of this study is to verify the feasibility of visual CAP scoring with only one channel of EEG, the evaluation of the inter-scorer agreement in a variety of recordings, and the comparison of the visual scorings with a known automatic scoring system. Sixteen hours of one channel (C4-A1 or C3-A2) of NREM sleep were extracted from eight whole night recordings in European Data Format and presented to the different scorers. The average inter-scorer agreement for all scorers is above 70 percent, the pair wise inter-scorer agreement found was between 69 percent up to 77.5 percent. These values are similar to what has been reported in different type studies. The automatic scoring system has similar performance of the visual scorings. The study also has shown that it is possible to classify the CAP using only one channel of EEG.


A classificação dos eventos de curta duração no EEG durante o sono, como a fase A do padrão alternante cíclico (CAP) é tarefa tediosa e propensa ao erro. O número de eventos é geralmente grande (centenas ao milhar), e é necessário marcar os limites dos eventos com precisão, caso contrário tanto a classificação das duas fases do CAP como a distinção dos diferentes tipos de fases A podem ser comprometidas. O objetivo deste estudo é a avaliação da concordância inter-estagiadores no CAP tanto visual quanto automático usando um único canal de EEG, a avaliação do acordo inter-estagiadores em uma variedade das gravações, e a comparação das classificações visuais com um sistema classificador automático. Dezesseis horas de um canal (C4-A1 ou C3-A2) do sono de NREM foram extraídas de oito gravações inteiras da noite no Formato de dados Europeus e apresentadas a diferentes classificadores, o acordo médio inter-estagiadores para todas as classificações está acima de 70 por cento, o acordo inter-estagiadores do par encontrado entre 69 por cento até 77,5 por cento. Estes valores são similares ao que foi relatado nos diferentes tipos de estudos. O sistema marcador automático tem o desempenho similar aos dos classificadores visuais. O estudo também mostrou que é possível classificar o CAP usando somente um canal de EEG.


Subject(s)
Humans , Electronic Data Processing , Electroencephalography/methods , Polysomnography , Sleep Stages/physiology , Observer Variation , Reference Values , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL